Problem: During step 4 of the workflow there is an ASPSuite notification stating, “Error: No external camera events found!”. Probable Resolution #1: Verify that you’ve used the correct Loki MEP workflow. https://support.geocue.com/forums/topic/which-loki-mep-interface-workflow-should-i-use/ Probable Resolution #2: When using the DJI USB Cable workflow it is important to remember that you need to download the applicable DAT…
In ASPSuite, the Enable Base Antenna Calibration option uses an *.atx file to set custom offsets for the brand and model of the base station used. At https://www.ngs.noaa.gov/ANTCAL/, a user may navigate to “Browse Antenna Information by Manufacturer and Model” and select the brand from the dropdown menu. Next, find the correct model and right-click…
Below are approximate Loki battery life times at different tested temperatures: 20 C / 68 F: 2h 30m until the battery LED transitions to RED; 30m or less remaining. 4 C / 40 F: 1h 55m to RED; 22m or less remaining. -16 C / 3 F: 1h to RED; 12m or less remaining. To…