What’s New in Terrasolid? – Jan 2020

The following are the highlights of the new features that have been added to the Terrasolid software between February 2019 and January 2020, and can be found in the version 020 releases. Various Improvements Thin points has new choices to keep first/last echo or whole pulse Note text field added to Modify Tree Cells and…

Share

Adding WMS or Background Maps to MicroStation CE

Adding a WMS or background map to MicroStation CE or the other Bentley products when working with TerraScan can enhance the user experience and provide an imagery reference for reviewing LIDAR data classification and features. To Add a WMS: https://docs.bentley.com/LiveContent/web/MicroStation%20Help-v15/en/GUID-0DA35A47-921C-6905-D209-42CFBBC4B52F.html To Add a Background Map such as Bing Maps: https://docs.bentley.com/LiveContent/web/MicroStation%20Help-v15/en/GUID-E349623C-B31E-4837-9C86-AEB08DA89896.html

Share

LASSymbols.DLL Failed to register

Symptom: While installing LP360 or True View EVO user encounters the error, “Module C:\Program Files\Common Files\LP360\LASSymbols.dll failed to register.” (v2018.1 and later) or “Module C:\Program Files\Common Files\QCoherent\LASSymbols.dll failed to register. HRESULT -1073740940” (version prior to v2018.1). Multiple errors of a similar nature for other DLLs also occur if one continues with the installation. Download and…

Share

Switching Languages in LP360 or True View EVO

KBA-01041-Y0B3V6 Question How do I switch the language being used by LP360 or True View EVO? Answer LP360 by default will launch in English, unless it’s running on an operating system that is a supported language. Currently the supported languages are Spanish, Japanese and Polish.   For LP360 (both 32-bit and 64-bit), LPViewer, and True View EVO:…

Share

Positioning Options in True View Workflows

What is POSPac? True View 3D imaging System (3DIS) uses Applanix APX Position and Orientation Systems (POS). The POS is a GNSS-aided Inertial Navigation System that provides the precise position and orientation of the sensor at a rate of 200 observations per second. This information is needed to “geocode” LIDAR and determine the exterior orientation of images. Applanix…

Share

ASPSuite Error: Loki Rover Observation and Navigation Files do not exist

To use the SBF file (Loki file), ASPSuite will convert it into Rinex observation and navigation files during the file conversion step (Step 2).  If the SBF file has not been converted, and the observation and navigation files are not in the project folder, the error, “Loki Rover Observation and Navigation Files do not exist:”,…

Share