LP360 Short Tutorial – Feature Edit Part 3: Downstream Constrained

Learn about creating, validating and editing vertices of downstream constrained features in LP360 using the downstream constraint setting of the Conflation Point Cloud Task. This short tutorial is designed to introduce the user to creating hydrological breaklines with proper downstream flow using the Feature Edit toolbar.

Share

Manually Install TerraSlaveService

The TerraSlaveService is required in order to use a machine as a slave machine for the TerraDispatcher. If the TerraSlaveService does not install as it should using the setup.exe, manually install the service. Open an elevated command prompt by right-clicking on Command Prompt in the Start menu and selecting “Run as Administrator”. Type “sc create…

Share

Verifying Number of External Events Recorded by Loki

When using Loki with the Inspire 2 Personality cable, DSLR cable, or direct hardwire camera cable, the number of external events recorded can be confirmed by opening the sbf.blocks.txt file in the PPK folder in the ASPSuite project folder (root folder). There should be a block (highlighted in the image above) that begins with “#…

Share

County Coordinate Systems in Terrasolid

To configure county coordinate systems in either TerraScan or TerraPhoto, ascertain the proper metric projection values for the desired county system. In the GeoCue workflow management software, these can be found on the Coordinate System Picker dialog or in the GeoCue Common Folder. In LP360 or True View EVO, they are found in the Coordinate…

Share

LoadLibrary failed with error 87

Starting LP360 or True View EVO results in “LoadLibrary failed with error 87. The parameter is incorrect.” error. This indicates a graphics card driver issue. Several fixes include either renaming an ATI driver dll, rolling back the display driver to an older version, or replacing the video card with an NVIDIA one. This error may…

Share

No more valid machines available for processing

The task or subtask messages column of the GeoCue Dispatch Manager states, “No more valid machines available for processing” or ” No other valid machines available for re-processing”. The task, such as Archiving, is configured, to dispatch to only the machine from which it was started. An error was encountered during archiving and no additional…

Share

Error Message: System Clock has Been Set Back (-40)

While attempting to check out a license in LP360, True View EVO, or ASPSuite, the user receives an error message, “LP360 is unable to perform requested licensing task. Details: System clock has been set back (-40)” The system clock must be set to the proper date and time for licensing to work properly.

Share

LP360 Failed to Start as it Could Not Obtain a Valid Product License (22641)

Receive an error message when starting LP360 or True View EVO stating, “LP360 Failed to Start as it Could Not Obtain a Valid Product License (22641)”. Version 2018.1 or newer The user has entered an invalid license string. This error message would have been preceded by one stating, “Invalid License String“. Verify the License String…

Share