This set of steps will specify the shapefile to which the Volumetric output polygon is written.
Set up a new Volumetric Analysis task.
Click the Volume tab.
Click the browse button next to the Output Polygon File field. The I/O Manager will display again.
In the available drop-down menu under File/Folder, click the folder button and then type a filename and browse to a location in which to save the output SHP file that will contain the volume properties. Click Save.
In the Output Mode list, select Append to combine the new file with an existing file, or Overwrite to replace an existing file.
Click the Add to Map checkbox (also in the Volumetric Output Polygon row) if you want to add the output file as a layer to the map.
Close the I/O Manager.
Set the Volume Computation Method to Cut - Fill, Fill - Cut, Cut, or Fill.
Set the Output Volume Units. These can be in Feet, Yards, or Meters.
Check any of the additional output attributes that you want. These can be Cut Volume, Fill Volume, or Diagnostic Attributes
Click Apply at the bottom of the window to continue.