Import Multiple Scanner Data

GeoCue has the ability to import source LIDAR strips with multiple scanners and assign the scanner number to the User Byte in the LAS format. The User Byte is what TerraScan uses for the scanner since no scanner attribute existed before LAS v1.4, and the field, even in LAS v1.4 is limited to a small…

Share

Setting the screen resolution and Scale

Problem: Many new laptops come with very high resolution screens, causing text and icons in various software packages to appear very tiny, or badly sized. Probable Solution: Reduce the screen resolution to 1920 x 1080 and scale the text to 100%, or as desired.

Share

CueTip – County Coordinate Systems

When working with data in county coordinate systems, the definitions of datum transformations are important. The steps in this CueTip provide recommendations and an example of such a project; beginning from project setup, to selecting appropriate Coordinate Reference Systems (CRSs), to properly defining the coordinate transformations. Please consult with your surveyor to determine the appropriate…

Share

Regedit for Population Error

Problem: While attempting to populate LAS Working Segments the process errors with an exception. In the system message column of the Checklist Step History you note the following exception: System.ArgumentException: Source array was not long enough. Check srcIndex and length, and the array’s lower bounds. at System.Array.Copy(Array sourceArray, Int32 sourceIndex, Array destinationArray, Int32 destinationIndex, Int32…

Share

CDS Processing Priority

In the GeoCue Command Dispatch System (CDS) the Processing Priority (or simply priority) determines the processing order of subtasks that could otherwise process in any order. Priority in the CDS is a floating point number ranging from 0.0 to MAX_FLOAT. Higher values are considered higher priority. For example, assume that two LIDAR Orthos are in the…

Share

RunMacro Exception: System.Exception: Unable to ReadFileNumber after 1000 attempts

Problem: Attempting to Run Macro in GeoCue results in a “RunMacro Exception: System.Exception: Unable to ReadFileNumber after 1000 attempts” error message in the System Messages of the Checklist Step history. Probable Resolution #1: Verify that the GeoCue temp folder has been set by opening Configure Client.  Also, verify that the path in “GeoCue Temp Folder”…

Share

Using FileZilla to Exchange Files with GeoCue Group Support

At times while working with GeoCue Group Support it may become necessary to exchange large files or large numbers of files. We suggest the use of an FTP Client to make this easier. If you don’t have your own, or are not familiar with using an FTP client we suggest using the FileZilla project. FileZilla…

Share

Trajectories for Run Macro Step

Problem: When running a macro through TerraSlave from GeoCue, routines that depend upon trajectory information can fail to return any results.  These routines include “Cut Overlap-Cut by Offset option” and “Apply Corrections”. Cause: When assigning and running a macro through TerraSlave from GeoCue, there is no setting to select which trajectory layer to use as…

Share

TerraScan Raster Backdrop

If you choose to load backdrop images while editing in TerraScan (while through GeoCue’s Process in TerraScan, DirectDrive, or directly in MicroStation’s Raster Manager) and your images show up in the wrong place relative to your LAS points, MicroStation’s Raster Manager may be interpreting your TFW (sister file) or coordinates incorrectly.  Raster Manager defaults the…