GeoCue’s repository of TrueView tools, tips and workflows for the TrueView line of drone mapping products. Includes former AirGon products such as Loki and ASPSuite.
Problem: In LP360 for ArcGIS, while trying to Define the 3D Window’s Extent, LP360 errors stating, “Getting Spatial References Failed (17124)”. Expanding the error message dialog for more information reveals, “QI to ISpatialReference failed (21422)”. Probable Resolution: The most probable cause is the lack of a Spatial Reference System (SRS) specified on the LAS Layer…
Problem: In LP360 for ArcGIS, while trying to Draw a Profile Line, LP360 errors stating, “Completing the construction of the profile line failed. (17020)”. Expanding the error message dialog for more information reveals, “QI to ISpatialReference failed (21422)”. Probable Resolution: The most probable cause is the lack of a Spatial Reference System (SRS) specified on…
The density of point clouds (usually expressed as points per square meter) is increasing on what seems to be a monthly basis. This is particularly true of point clouds derived from Dense Image Matching (DIM), the clouds produced from software such as PhotoScan, Pix4D, DroneDeploy and so forth. You can quickly check the density of…
Reckon has been deprecated and replaced by LP360 Online, including the LP360 Portal and LP360 Cloud. Reckon is AirGon’s Amazon Web Services cloud hosted data management and delivery system. Service providers use Reckon to deliver content and volumetric results to their customers, whereas owner-operators use Reckon to directly manage their analytic results. Reckon provides multiple…
Symptoms: In ASPSuite, the ephemeris download fails. It just does nothing. Probable Resolution #1: Verify your machine has a proper internet connection and try again. Probable Resolution #2: Verify the ephemeris file is available. The broadcast ephemeris is available immediately, the ultra-rapid should be available within six hours of your flight. Probable Resolution #3: Manually…
Problem: In ASPSuite, processing the Interpolating Camera Events step results in an, “Error: Rover Position File (.pos) is Empty”. Probable Solution #1: The base station coordinate was entered incorrectly. Check the base station coordinate and be sure that southern latitudes and western longitudes have a negative sign. Note the base station must be entered in…
LP360 can be inefficient when working with very dense point clouds, such as Dense Image Matching, for ground classification if appropriate steps are not taken in the workflow. In fact, be aware that it simply crashes if you have to use a large seed size (e.g. 200 feet on some machines) that requires more points…
Problem: When I click apply my point cloud task does not execute. Probable Resolution: Clicking apply only saves the changes you made to the Point Cloud Task (PCT). To execute a PCT one must use one of the execute tools located on the Point Cloud Task toolbar.
Problem: A check of the ASPSuite License shows Current License as “Unlicensed” and shows Available Licenses as “0 of 0”, but the Check Out License button is enabled. Attempting to check out a license in this state will result in an error, “Failed to checkout roaming license. Failed to checkout the license for ASP. Reason:…
Beginning with version 2017.1 of LP360, users have the capability to edit the attributes (Add fields and values) of shapefiles. In LP360, fields are added/removed via the Schema Editor and values modified using Feature Analyst: The Schema editor is used to manage the fields of the shapefile, hence it is used to add/remove fields: A…