GeoCue Support » Archives for GeoCue Support » Page 37
After updating/upgrading a program, double-clicking the shortcut fails to open and gives this dialog shown in figure 1, stating, Problem with Shortcut: The parameter is incorrect.”. What is the target (right click the shortcut > properties) for the shortcut? This can also be found going to “Open File Location” in the context menu. You can…
To modify the number of subtasks that are launched when Dispatching/Distributing from GeoCue, consider customizing Machine Resources. (Note that these are advanced GeoCue settings and require GeoCue Administrator level privileges). The factors that need to be considered when fine-tuning your Command Dispatch System are: 1. Available Machine Resources Resources available per machine are controlled by:…
When Cookie Cutting by Polygons in LP360 Export Wizard, Apply Buffer to Polygons doesn’t apply a buffer to the exported data. In LP360 Standalone (64-bit) the apply buffer tool has not been implemented yet. LP360 for ArcMap (32-bit) will correctly generate the buffered output required.
A macro fails when launched through Geocue Dispatch. Checklist Step Details, System Messages error reads “No design files on the working segment”. Additionally, reviewing the Sub Tasks for the specified task on the Dispatch Manager reveals the machine timing out and returning to pending queue. If the macro is set up to run in TerraScan:…
My Design File has unique information that is required for my macro to run. How can I set Design Files and dispatch that macro through Geocue? Access “Set Population Parameters” though the working set you wish to assign the Design File (DGN) to. When the dialogue box appears, choose the Feature File drop down menu.…
After installing LP360 for ArcGIS, when you try to run the program it throws an error stating, “Ordinal Not Found: The ordinal 3873 could not be located in the dynamic link library (SSLEAY32.dll)”. Note: The ordinal number and the DLL may be different in the specific error message you see. The error is likely occurring after you run…
Attempting to run the adaptive TIN ground filter on a Dense Image Matching (DIM) point cloud does not classify any points. When a point cloud is created from a Dense Image Matching process, the resulting LAS produced by some software is not classified (0) and has 0 of 0 returns. Identifying points in LP360 will…
To assign or modify the Spatial Reference System (SRS) in a LAS file, use the LP360 LAS File Analyst tool: Add the LAS files into LP360 as open for Read/Write. Select “LAS File Analyst” by right-clicking the LAS layer, or clicking the wrench and hammer icon associated with the main LP360 toolbar. A dialogue box…
Use Live View to change the point size in the profile or other desired window(s). When you click the yellow funnel looking tool the LP360 Live View dialog will appear. Here you can modify the synchronize views to only modify the profile window, or other desired views, so that when you adjust the point size…
For LP360 versions 2018.2.59.5 or later: The LDExport tool provides a quick means of generating a shapefile index of your LAS files and no longer requires a settings file. Execute the following in a command line, where the LAS files are located in “D:\Training_Data\Davidson_TN_2016\LAS” and the index file is to be generated in “D:\Training_Data\Davidson_TN_2016\LAS”. To…